Mostra el registre parcial de l'element

dc.contributorUniversitat Ramon Llull. Facultat de Ciències de la Salut Blanquerna
dc.contributor.authorPuig-Diví, Albert
dc.contributor.authorEscalona Marfil, Carles
dc.contributor.authorPadullés Riu, Josep Maria
dc.contributor.authorBusquets, Albert
dc.contributor.authorPadullés-Chando, Xavier
dc.contributor.authorMarcos-Ruiz, Daniel
dc.date.accessioned2019-06-30T15:28:39Z
dc.date.accessioned2023-07-12T12:05:45Z
dc.date.available2019-06-30T15:28:39Z
dc.date.available2023-07-12T12:05:45Z
dc.date.created2018-05
dc.date.issued2019-06
dc.identifier.urihttp://hdl.handle.net/20.500.14342/775
dc.description.abstractAn objective analysis of the human movement can help both clinical assessment and sports performance. Kinovea is a free 2D motion analysis software that can be used to measure kinematic parameters. This low-cost technology has been used in sports sciences, as well as in the clinical and research fields. One interesting tool is that it can measure an object (or person) passing in front of the camera, taking into account the perspective between the camera and the recorded object. Although it has been validated as a tool to assess time-related variables, few studies assessed its validity compared to a Gold Standard; furthermore, its reliability in different perspectives has not been previously assessed. The main objective of this study is to determine the validity of the Kinovea software compared to AutoCAD, and its intra and inter-rater reliability in obtaining coordinates data; a second objective is to compare their results at 4 different perspectives (90°, 75°, 60° and 45°) and to assess the inter and intra rater reliability at each perspective. For this purpose, a wire structure figure in the shape of a human lower limb was designed and measured in AutoCAD; it was then recorded during a pendular motion with a video-camera placed at distance of 5 m and analyzed with Kinovea in the 4 perspectives (90°, 75°, 60° and 45°). Each frame was examined by three observers who made two attempts. A multiple approach was applied involving the analysis of the systematic error, with a two-way ANOVA 2x4; the relative reliability with Intraclass Correlation Coefficient (ICC) and the Coefficient of Variance (CV) (95% confidence interval); and the absolute reliability with the Standard Error (SE). The results indicate that the Kinovea software is a valid and reliable tool that is able to measure accurately at distances up to 5 m from the object and at an angle range of 90°–45°. Nevertheless, for optimum results an angle of 90° is suggested.eng
dc.format.extent14 p.cat
dc.language.isoengcat
dc.publisherPublic Library of Science (PLoS)cat
dc.relation.ispartofPLoS One, 2019, vol. 14, núm. 6cat
dc.rightsAttribution 4.0 International
dc.rights© L'autor/a
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.sourceRECERCAT (Dipòsit de la Recerca de Catalunya)
dc.subject.otherCinesiologiacat
dc.subject.otherBiomecànicacat
dc.subject.otherAparell locomotor--Propietats mecàniquescat
dc.subject.otherProgramaricat
dc.titleValidity and reliability of the Kinovea program in obtaining angles and distances using coordinates in 4 perspectivescat
dc.typeinfo:eu-repo/semantics/articlecat
dc.typeinfo:eu-repo/semantics/publishedVersioncat
dc.rights.accessLevelinfo:eu-repo/semantics/openAccess
dc.embargo.termscapcat
dc.subject.udc612
dc.identifier.doihttps://dx.doi.org/10.1371/journal.pone.0216448cat


Fitxers en aquest element

 

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Attribution 4.0 International
Excepte que s'indiqui una altra cosa, la llicència de l'ítem es descriu com http://creativecommons.org/licenses/by/4.0/
Comparteix a TwitterComparteix a LinkedinComparteix a FacebookComparteix a TelegramComparteix a WhatsappImprimeix