Mostra el registre parcial de l'element

dc.contributorUniversitat Ramon Llull. Facultat de Psicologia, Ciències de l’Educació i de l’Esport Blanquerna
dc.contributorUniversitat Ramon Llull. Facultat de Ciències de la Salut Blanquerna
dc.contributor.authorOviedo, Guillermo R.
dc.contributor.authorGarcia Retortillo, Sergi
dc.contributor.authorCarbó-Carreté, Maria
dc.contributor.authorGuerra Balic, Míriam
dc.contributor.authorBalagué, Natàlia
dc.contributor.authorJavierre, Casimiro
dc.contributor.authorGuàrdia Olmos, Joan
dc.date.accessioned2022-02-23T07:57:48Z
dc.date.accessioned2023-07-13T08:18:24Z
dc.date.available2022-02-23T07:57:48Z
dc.date.available2023-07-13T08:18:24Z
dc.date.issued2021
dc.identifier.urihttp://hdl.handle.net/20.500.14342/2352
dc.description.abstractIntroduction: Down syndrome (DS) is a chromosomal disorder affecting simultaneously cardiovascular and respiratory systems. There is no research studying the coupling between these systems during cardiorespiratory exercise testing in a population with DS. Cardiorespiratory coordination (CRC), evaluated through principal component analysis (PCA), measures the covariation of cardiorespiratory variables during exercise. Objective: To investigate and compare CRC in adults with and without DS during maximal cardiorespiratory exercise testing. Methods: Fifteen adults with DS and 15 adults without disabilities performed a maximal cardiorespiratory exercise test on a treadmill. First, the slope, and afterward the velocity was increased regularly until participants reached exhaustion. The time series of six selected cardiorespiratory variables [ventilation per minute, an expired fraction of O2, the expired fraction of CO2, heart rate, systolic blood pressure (SBP), and diastolic blood pressure (DBP)] were extracted for the analysis. The number of principal components (PCs), the first PC eigenvalues (PC1), and the information entropy were computed for each group (non-DS and DS) and compared using a t-test or a Mann-Whitney U test. Results: Two PCs in the non-DS group and three PCs in the DS group captured the variance of the studied cardiorespiratory variables. The formation of an additional PC in the DS group was the result of the shift of SBP and DBP from the PC1 cluster of variables. Eigenvalues of PC1 were higher in the non-DS (U = 30; p = 0.02; d = 1.47) than in the DS group, and the entropy measure was higher in the DS compared with the non-DS group (U = 37.5; p = 0.008; d = 0.70). Conclusion: Adults with Down syndrome showed higher CRC dimensionality and a higher entropy measure than participants without disabilities. Both findings point toward a lower efficiency of the cardiorespiratory function during exercise in participants with DS. CRC appears as an alternative measure to investigate the cardiorespiratory function and its response to exercise in the DS population.eng
dc.format.extent10 p.cat
dc.language.isoengcat
dc.publisherFrontierscat
dc.relation.ispartofFrontiers in Psychology, 2021, Vol. 12, article 704062cat
dc.rightsAttribution 4.0 International
dc.rights© L'autor/a
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.sourceRECERCAT (Dipòsit de la Recerca de Catalunya)
dc.subject.otherDown, Síndrome decat
dc.subject.otherPressió sanguíniacat
dc.subject.otherExercici cardiorespiratoricat
dc.titleCardiorespiratory Coordination During Exercise in Adults With Down Syndromecat
dc.typeinfo:eu-repo/semantics/articlecat
dc.typeinfo:eu-repo/semantics/publishedVersioncat
dc.rights.accessLevelinfo:eu-repo/semantics/openAccess
dc.embargo.termscapcat
dc.identifier.doihttps://doi.org/10.3389/fphys.2021.704062cat
dc.relation.projectIDinfo:eu-repo/grantAgreement/MINECO/PN I+D/DEP2017–86862-C2–1-Rcat
dc.relation.projectIDinfo:eu-repo/grantAgreement/MCIU-AEI/PN I+D/PGC2018-095829-B-I00cat
dc.relation.projectIDinfo:eu-repo/grantAgreement/URL i SUR del DEC/Projectes recerca PDI/2021-URL-Proj-042cat


Fitxers en aquest element

 

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Attribution 4.0 International
Excepte que s'indiqui una altra cosa, la llicència de l'ítem es descriu com http://creativecommons.org/licenses/by/4.0/
Comparteix a TwitterComparteix a LinkedinComparteix a FacebookComparteix a TelegramComparteix a WhatsappImprimeix