A POCIS-based approach for the monitoring of pharmaceuticals in wastewater treatment plants: Calibration and deployment challenges
View/Open
This document contains embargoed files until 2027-02-15
Other authors
Publication date
2025-02-15ISSN
1873-6424
Abstract
The impact of pharmaceuticals in aquatic environments requires complementary monitoring techniques to the more conventional grab sampling approach for an improved sample representativity. This study explores the application of Polar Organic Chemical Integrative Samplers (POCIS) in the analysis of a wide range of pharmaceutical residues in wastewater effluent, highlighting its advantages over grab sampling. Passive sampling techniques, extending sampling duration several days or weeks, provide continuous and representative data, improving the punctual nature of grab sampling. Despite their advantages, achieving quantitative results remains a challenge. Calibration through precise determination of sampling rates (RS) is recommended to convert the accumulated contaminant mass on the adsorbent to water concentrations. In the present work, 78 pharmaceuticals were preselected for stability suitability for POCIS passive sampling. RS were experimentally determined for 49 stable compounds: 33 of them had not been previously reported and most the other 16 agree with previous published literature. These RS were used to determine the concentration of pharmaceuticals in a wastewater treatment plant (WWTP) near to Barcelona, Spain over 3 weeks. High concentrations of 1,7-dimethylxanthine (2897 ng L-1), 4-acetamidoantipyrine (191 ng L-1), acetaminophen (165 ng L-1) and rasagiline (152 ng L-1) were found. This study examines POCIS deployment strategies, calibration, and analysis methods for 49 pharmaceutical compounds in an WWTP effluent. This research establishes a robust methodology for quantitative passive sampling of pharmaceuticals in aquatic environments, providing critical insights for more accurate monitoring of pharmaceuticals of environmental concern.
Document Type
Article
Document version
Accepted version
Language
English
Subject (CDU)
502 - The environment and its protection
615 - Pharmacology. Therapeutics. Toxicology
Keywords
Environmental monitoring
POCIS
Passive sampler
Pharmaceutical residues
Sampling rates
WWTP
Seguiment ambiental
Indústria farmacèutica--Residus
Mostreig
Pages
p.45
Publisher
Elsevier
Is part of
Environmental Pollution 2025, 367
Grant agreement number
info:eu-repo/grantAgreement/MCI/PN I+D/PID2020-113371RA-C22
info:eu-repo/grantAgreement/MCI/PN I+D/PID2020-113371RB-C21
info:eu-repo/grantAgreement/MCI i AEI/PN I+D/TED2021-130845A-C32
This item appears in the following Collection(s)
Rights
© Elsevier
Except where otherwise noted, this item's license is described as http://creativecommons.org/licenses/by-nc-nd/4.0/