Show simple item record

dc.contributorUniversitat Ramon Llull. Facultat de Psicologia, Ciències de l'Educació i de l'Esport Blanquerna
dc.contributor.authorSolana-Tramunt, Mònica
dc.contributor.authorBuscà Safont-Tria, Bernat
dc.contributor.authorMorales Aznar, José
dc.contributor.authorMiró, Adrià
dc.contributor.authorAguilera-Castells, Joan
dc.contributor.authorArboix-Alió, Jordi
dc.date.accessioned2023-11-13T12:29:48Z
dc.date.available2023-11-13T12:29:48Z
dc.date.issued2020-06
dc.identifier.urihttp://hdl.handle.net/20.500.14342/3583
dc.description.abstractThe effects of wearing an intra-oral device on several ventilatory and fatigue markers have been reported for a variety of sports. The quality of the figures performed in synchronized swimming is directly affected by fatigue, and can be monitored during training sessions (TS). The aim of the study was to investigate the acute effects of wearing customized intra-oral devices on heart rate variability, rating of perceived exertion, blood lactate accumulation, and salivary cortisol production during a competitive training session. Twelve highly trained elite female athletes (age: 21.0±3.6 years) participated in the study. Fatigue markers were assessed at the beginning and at the end of the 3rd and 5th afternoon TS for that week, once with and once without an intra-oral device, in random order. Salivary cortisol levels were higher in relation to the baseline in the intra-oral device condition (P<0.05) but not in athletes without an intra-oral device. No differences between conditions were found in rating of perceived exertion (P=0.465) and blood lactate (P=0.711). No time or condition interactions or main effects were shown for heart rate variability. Thus, there is no evidence that wearing a low-arch intra-oral device is a good recommendation for high-standard athletes performing long and stressful routines.ca
dc.format.extent15ca
dc.language.isoengca
dc.publisherThiemeca
dc.relation.ispartofInternational Journal of Sports Medicine, 2020; 41(12): 839-845ca
dc.rights© Thieme. Tots els drets reservatsca
dc.subject.otherProtectors bucalsca
dc.subject.otherEsportsca
dc.subject.otherNedadorsca
dc.titleEffects of Wearing a Jaw-repositioning Intra-oral Device in Synchronized Swimming Athletesca
dc.typeinfo:eu-repo/semantics/articleca
dc.rights.accessLevelinfo:eu-repo/semantics/openAccess
dc.embargo.terms12 mesosca
dc.identifier.doihttps://doi.org/10.1055/a-1179-5806ca
dc.description.versioninfo:eu-repo/semantics/acceptedVersionca


Files in this item

 

This item appears in the following Collection(s)

Show simple item record

Share on TwitterShare on LinkedinShare on FacebookShare on TelegramShare on WhatsappPrint